Literature Review: Results of Leukocyte and Platelet Cell Examination Using The Counting Chamber And Hematology Analyzer Methods

Main Article Content

Rizaldy Djibran (*) Sandhidjibran@gmail.com
Tri Dyah Astuti

(*) Corresponding Author

Abstract

The hematology examination is a crucial component of clinical diagnosis, particularly for assessing the quantities of blood cells, including leukocytes and platelets. This examination employed two prevalent methods: the manual approach utilizing a counting chamber (Improved Neubauer) and the automatic way employing a Hematology Analyzer. This literature review aims to evaluate the outcomes of leukocyte and platelet analyses between the two methodologies. Data searches were performed using the PubMed and Google Scholar databases for papers published from 2013 to 2023. A total of 10 journals that satisfied the inclusion criteria were subjected to qualitative descriptive analysis. The review findings indicated that the automated method generally provides outcomes that are quicker, more precise, and more consistent compared to the manual method. However, the manual technique remains relevant in certain circumstances such as remote laboratories or in the absence of automated instruments. There are significant differences in the examination results of the two procedures for both leukocytes and platelets; therefore, the selection of method should be adjusted to the specific conditions and clinical requirements of each healthcare facility.

Downloads

Download data is not yet available.

Article Details

How to Cite
Djibran, R., & Astuti, T. D. (2025). Literature Review: Results of Leukocyte and Platelet Cell Examination Using The Counting Chamber And Hematology Analyzer Methods. Menara Journal of Health Science, 4(2), 174–186. Retrieved from https://jurnal.iakmikudus.org/article/view/256
Section
Articles

References

Andika R. 2017. Perbedaan Jumlah Trombosit Pada Darah Kapiler Dan Vena Penderita DBD. Skripsi. Universitas Muhammadiyah. Semarang.

Babadoko A.A. dkk. 2016. Reproducibility of Hematological Parameteres : Manual Versus Automated Method. African Journal of Medicine. Vol 3, p 65- 70. DOI: 10.4103/2384-5147.184352.

Bakhri, S. 2018. Analisis Jumlah Leukosit dan Jenis Leukosit Pada Individu Yang Tidur Dengan Lampu Menyala dan Yang Dipadamkan. Jurnal Media Analis Kesehatan, Vol.1, 86.

Darmayani, S., Fonnie, E., Hasan., & Devi, E. F. A. 2016. Perbedaan Hasil Pemeriksaan Jumlah Leukosit Antara Metode Manual Improved Neubauer dengan Metode Automatic Hematology Analyzer. Thesis. Poltekkes Kemenkes. Kendari

Durachim, A dan Astuti, D. 2018. Hemostasis. Jakarta : Kemenkes RI.

Gandasoebrata R. 2013. Penuntun Laboratorium Klinis. Dian Rakyat. Jakarta

Kawahara, R. and Shiozawa, Y. (2015) “Hematopoiesis ☆ Methods to Study Hematopoiesis Hematopoietic Stem Cell Markers Hematopoiesis During Development,” Elsevier Inc., (December 2014), pp. 1–4. doi:10.1016/B978-0-12-801238-3.05054-6.

Keohane E.M, 2016. Hemoglobin Metabolism in Rodak’s Hematology Clinical Principles and Applications, Fifht Edition, Elsevier Saunders, p 124-136

Linda, Ramadhan A, Tureni D. 2014. Pengaruh ekstrak biji pala (Myristica fragrans) terhadap jumlah eritrosit dan leukosit pada tikus putih (Rattus norvegicus). E-Jipbiol., 3: 1-8.

Tuntun, M., & Rahayu, P. 2019. Pengaruh Menstruasi Terhadap Profil Hematologi Pada Siswi SMPN 22 Bandar Lampung. Jurnal Analis Kesehatan,8(2); 34-42.

Pujiastarini, E. 2014. Pengaruh Penyimpanan Darah EDTA Terhadap Jumlahdan Morfologi Sel .Skripsi. Poltekkes Kemenkes. Yogyakarta

Praptomo, A. (2018). PERBANDINGAN HASIL PEMERIKSAAN HITUNG JUMLAH TROMBOSIT METODE LANGSUNG (REES ECKER),METODE TIDAK LANGSUNG (FONIO), DAN METODE AUTOMATIK (HEMATOLOGI ANALYZER). Jurnal Medika : Karya Ilmiah Kesehatan, 1(1), 1-12. Retrieved from https://jurnal.itkeswhs.ac.id/index.php/medika/article/view/34

Riswanto. 2013. Pemeriksaan Laboratorium Hematologi Selayang Pandang. Alfamedia. Kanal Medika.Jakarta

Sacher A Ronald. 2012. Tinjauan Klinis Hasil Pemeriksaan Laboratorium. Edisi 11. EGC. Jakarta.

Siska, A. 2020. Perbedaan Hasil Pemeriksaan Jumlah Leukosit Antara Metode Manual Improved Neubauer dengan Metode Automatik Hematologi Analyzer di RSUD M. Natsir Solok. Skripsi. D-IV Teknologi Laboratorium Medis. Universitas Perintis Indonesia. Padang